Use BinMaster Capacitance Probes for Sanitary Applications (PROCAP I3A and PROCAP II3A) for high and low-level detection in bins, silos, tanks, hoppers, chute, and other vessels used for the storage or manufacture of food or dairy products. Capacitance probes detect material in contact with the probe by sensing minute changes in capacitance caused by the difference in the dielectric constant of the material versus the air. They feature interference-free operation, simple calibration, and fail-safe functionality. The probes perform accurately in dusty, sticky or clinging materials and have Class II hazardous location ratings. 

Not what you’re looking for? Return to Level Indicators & Controls or call the experts at Gulf Atlantic: (800) 792-7427.

Description

Specifications

  • PROCAP I3A power requirements: Universal power supply 24 to 240 V AC/V DC
  • PROCAP II3A power requirements: Selectable 115/230 V AC
  • Output relay: DPDT 10 amp at 250 V AC
  • Ambient temperature: -40°F to +185°F
  • Process temperature: Up to 250°F Delrin probe; up to 500°F Teflon probe
  • Pressure: 500 PSI
  • Housing enclosure: Die cast aluminum, USDA approved powder coat finish
  • Mounting: 1 inch or 2.5 inch sanitary flange
  • Enclosure type: NEMA 4X, 5, 9 & 12 housing
  • Approvals and certifications: Listed for Class II, Groups E, F & G hazardous locations